High temperature induced draft fan

  • High Temperature Induced Draft Fan for 600 C Service
  • High Temperature Induced Draft Fan for 600 C Service
High Temperature Induced Draft Fan for 600 C ServiceHigh Temperature Induced Draft Fan for 600 C Service

High Temperature Induced Draft Fan for 600 C Service

  • Product description: Induced draft fan for 600 C service: material selection, insulation and water-cooled bearing design, applicable processes and acceptance standards.
  • INQUIRY

Overview

600 C is firmly in heat resistant steel territory and usually comes with heavily dust laden gas. The main material is 12Cr1MoV, the bearing assembly is water cooled and the casing is lined with ceramic fibre, so temperature, wear and sealing are solved together.

Material Selection at 600 C

Pearlitic heat resistant steel provides the creep and oxidation performance needed at this level.

Location Material / process Basis
Impeller and casing 12Cr1MoV (GB/T 5310) Good creep and oxidation resistance at 600 C
Welding consumables Heat resistant electrodes (GB/T 5117) Maintains weld strength at temperature
Bearing assembly Water cooled bearing housing Removes bearing heat positively
Insulation 50 mm ceramic fibre lining plus external insulation Lowers metal wall temperature
Wear zones Hardfacing on blades and liner plates Combines temperature and abrasion resistance

Structural Measures at 600 C

Location Material / process Basis
Water cooled bearing housing Jacket with circulating water and temperature monitoring Keeps bearings within their limit
Expansion joints Bellows joints in hot ducts (GB/T 12777) Absorbs thermal displacement
Combined sealing Labyrinth seal with graphite packing Limits hot gas leakage
Welding procedure qualification Qualified procedure with test coupon Prevents weld cracking in service
Ceramic fibre anchoring Anchors fixed to the casing Stops the lining from collapsing

Applications

Typical duties are power plant boiler induced draft, cement kiln tail gas, coke oven gas and carbon rotary kilns.

Dust load is often high at this level, so wear resistance and temperature resistance have to be designed together.

Where dust load is high, a pre-collector ahead of the fan is recommended and the separation efficiency should be written into the technical agreement.

Acceptance and Verification

Standard Title Purpose
GB/T 5117 Covered electrodes for manual metal arc welding of non-alloy and fine grain steels Welding consumable matching
GB/T 1236 Industrial fans - Performance testing using standardized airways Air flow, pressure and efficiency testing
GB/T 12777 General specification for metal bellows expansion joints Expansion compensation for hot ducts and casing
GB/T 9239.1 / ISO 21940-11 Mechanical vibration - Balance quality requirements for rigid rotors Impeller balancing grade
GB/T 10178 Industrial fans - Performance testing in situ On-site performance verification

Please provide medium temperature, gas composition, dust load and air flow. Fan size and motor power are calculated for the actual duty.

FAQ

Does a water cooled bearing housing add failure points?

It adds cooling water management, but without water or forced cooling the bearing life at 600 C cannot normally be guaranteed. Water temperature, flow monitoring and a low flow alarm are recommended.

Does the impeller need hardfacing at 600 C?

For dust laden gas, yes. Hardfacing is normally applied to the wear prone areas and the rotor is re-balanced to G6.3 or tighter afterwards.

Why is welding procedure qualification emphasised?

Pearlitic heat resistant steels such as 12Cr1MoV are prone to hardening and cracking in the heat affected zone, and the risk grows during long term hot operation, so consumables, preheat and post weld treatment follow a written procedure.